SENC 50

As the result of its extremely compact dimensions, the SENC 50 linear encoder in many different types of applications and situations. It is especially suitable if the installation space is limited or otherwise restricted.

  • Compact dimensions
  • Resolutions from 0.5 µm to 5 µm
  • Output signals: TTL and sinusoidal
  • Measuring lengths from 50 mm to 525 mm
  • Distance-coded reference marks
SENC50
Measuring standardGlass scale with incremental graduation
Accuracy grade± 3 μm
Measuring length MLMounting spar optional
50 75 100 125 150 175 200 225 250 275 300 325 350 375 425
475 525
Incremental signalsTTLTTL x 5TTL x 1011 μASS
Grating period
Integrated interpolation
20 μm
without
20 μm
5-fold
20 μm
10-fold
20 μm
without
Signal period20 μm 4 μm 2 μm 20 μm 
Measuring step5 μm1 μm0.5 μm0.5 μm
Reference marksDistance-coded
without load5.1 V ± 0.1 V/< 180 mA5.1 V ± 0.1 V/< 220 mA5.0 V ± 0.1 V/< 75 mA
Electrical connectionCable in metal armor, with 9 pin D sub connector; length: 3 mCable with 9 pin D sub connector; length: 3 m
Cable length≤ 6 m (total length with ACU-RITE cable)
Traversing speed≤ 60 m/min
equired moving force≤ 2.2 N
Operating temperatureTemperature 0 to +50 °C; humidity 25% to 95% (no condensation forming)
Storage temperatureTemperature –20 to +70 °C; humidity 20% to 95% (no condensation forming)
Protection EN 60 529IP 53 when mounted according to the mounting instructions
Weight0.5 kg + 0.3 kg/m measuring length